Chemical Measurement Division


EPA Method 316

Formaldehyde (Mineral Wool & Wool Fiberglass)

Method Overview

  • • Isokinetic sampling.
  • • Sampling train and operating procedures are similar to M5 except that M316 requires reagent grade water in impingers.
  • • 30 cubic ft minimum sample volume.
  • • NOTE - High sulfite concentrations in the stack gas are a negative interferent. (Special precautions are available to detect and correct this problem.)
  • • Formerly known as the "NAIMA Method."
  • • Analysis is by the modified pararosaniline method, with spectrophotometer set at 570 nm.
  • • Validated for mineral wool fiberglass production facilities.

Target Compounds

  • • Formaldehyde

Method Summary

  • • The source is sampled isokinetically and formaldehyde absorbed in DI water. Samples are shipped to the lab cold.
  • • The impinger contents and DI train rinses are analyzed by spectrophotometer. At Enthalpy, samples are derivatized with pararosaniline and sodium sulfite to create a purple chromophore. The chromophore is analyzed by spectrophotometer set at 570 nm.
  • • Additional analytical details: Dilutions are made before the derivatizing reagent is added. Samples must be allowed to warm to room temperature just before reacting. Samples must react at least 1 hour before analysis. A slope of the calibration curve that is not within 10% of .5 reveals a problem with the standards or the instrument. The slope holds to Beer's Law; if the pathlength of each instrument is the same, the slope should likewise be the same save for minor differences from electronic processing.

Quality Assurance

  • • Field blank
  • • Lab QA: we prepare new sodium sulfite reagent every day, and each day prep and analyze new working standards.
  • • Enthalpy uses reagent water to set zero on the spectrophotometer.

Shipping Tips

  • • Hazardous shipping is not required unless formaldehyde concentrations are extremely high.
  • • Ship samples cold.
  • • Please include a completed Chain of Custody (COC) form with each cooler.
  • • See Enthalpy's Download page for a printable COC form.

Enthalpy Experience

  • • Enthalpy has nationwide environmental service contracts with clients in the mineral wool industry, and we analyze Method 316 samples regularly and often.
  • • Enthalpy uses a Hewlett Packard 8452 scanning diode array spectrophotometer, (which is a bit of a step up from the Milton Roy Spec 20 we ran in Chem Lab 101.)
  • • We have devoted considerable time and resources to discussing nuances and weaknesses of the method with the industry experts who developed it, and we can advise in advance when a test situation may prove inappropriate for the method.